Vertical Two-Zone Layout:
Designed with a vertically stacked hot and cold chamber configuration,
optimizing space utilization and facilitating easy operation and
maintenance.
Ball-Screw Driven Basket Transfer System:
Equipped with a ball-screw drive mechanism to ensure smooth and
reliable transfer of the test basket between hot and cold chambers,
enhancing stability during testing.
High Load Capacity Basket Design:
The two-zone chamber supports a maximum basket load of 20 kg, while the
three-zone model accommodates up to 50 kg, meeting a variety of testing
requirements.
Precise Temperature and Humidity Control:
The hot chamber operates from +50°C to +220°C (optional up to +250°C),
and the cold chamber from -80°C to +70°C, offering flexibility for
diverse testing scenarios.
Ensured Temperature Uniformity:
Optimized airflow design guarantees uniform temperature distribution
within the chamber, ensuring accurate and consistent test results.
No Compressed Air Required:
The system is designed to operate without an external compressed air
supply, simplifying installation and usage while reducing maintenance
costs.